SPECIFICATION:

•  For continuous non-contact level measurement
•  Suited to level measurement of various liquid and bulk-solid materials
•  Outstanding contrast OLED display
•  Easy adjustment without measured material
•  Quick view measured values on the display
•  Xi version for usage in explosive areas
•  Current output (4 ... 20 mA) with HART communication protocol

The ULM ®  ultrasonic level meters are compact measurement devices including an electroacoustics converter, central processor unit and display module. Using the electroacoustics converter, the level meters transmit the sequence of ultrasonic pulses that spread towards the surface level. The converter recuperates refl ected acoustic waves that are subsequently processed in the electronic module. The intelligent evaluation block fi lters out interfering signals, compares the cleaned received signal with the false refl ection map (e.g. from mixers, ladders, reinforcement etc.) and selects a suitable refl ection (echo). Based on the period during which the individual pulses spread towards the surface level and back and based on the measured temperature in the tank, the instant distance to the surface level is calculated. According to the level height, the level meter output is set and the measured value is displayed on the display.
The level meters are suited to level measurement of various liquid materials, sewerage waters, mash and paste materials, suspensions in closed or open vessels, sumps, reservoirs and open channels. In case the level of bulk-solid materials is measured, the measurement range is reduced. We recommend to consult the use with the manufacturer.

OTHER INFO.:
Measuring range:ULM-70_-02-I 0. 2…2M
ULM-70_-06-I 0. 25…6M
ULM-70_-10-I 0.4…10M
ULM-70_-20-I 0.5…20M
Supply voltage:ULM-70N-__-I 18…36VDC
ULM-70Xi-__-I 18…30V DC
Output:4…20mA (limit value 3.9 ... 20.5 mA), HART
Resolution:< 1mm
Accuracy (within the total range):0,15%
Temperature error:max. 0.04% / K
Beamwidth (-3 dB):ULM-70_-02;10-I 10°
ULM-70_-06-I 14°
ULM-70_-20-I 12°
Ambient temperature range:ULM-70_-02;06-I -30…+70°C
ULM-70_-10;20-I -30…+60°C
Short-time temperature stress resistance:+90°C / 1 hour
Max. operation overpressure (on transmission surface):0.1 Mpa
Sensitivity:3 steps (low – medium – high)
Damping:0 ... 99 sec.
Measuring period:1 ... 4 sec.
Delay between supply power rise time and fi rst measurement:30 sec.
Additional technical data 2) (only for variant Xi) – Max. internal values:U=30V DC; I=132mA; P=0.99W; C=370nF; L=0.9mH
Failure indication (echo loss, level in dead zone, internal failure):Adjustable in modes:
3.75 mA ; 22 mA ; last measured value
Protection class:IP67
Mechanical connection:ULM-70_-02-I screwing with thread G 1''
ULM-70_-06-I screwing with thread G 1½''
ULM-70N_10-I HDPE flange